Energy Design
During the design phase, identify the most cost-effective building configuration for your goals. Energy requirements, CO₂ emissions, and life-cycle costs are calculated for each option before you make a decision.
Decided early, checked late, often too late.
Building form, orientation, glazing ratio and the system concept determine most of the later energy demand. In the concept phase, these decisions are made on experience, not on simulation.
A robust comparison of design options across all criteria takes weeks and a large budget. In a tightly scheduled concept phase, that is rarely feasible.
Without a calculated basis, the energy concept and CO₂ pathway rest on assumptions, with the risk of missed energy ratings and oversized systems as a last resort.
What Is Energy Design?
Energy Design determines what a building really needs, from the right configuration for heating, cooling and ventilation to the right windows and facade insulation. All design options are simulated, individually and in combination, including the interdependencies between measures. Evaluated by operation, life cycle cost and CO₂ emissions, it becomes clear which option achieves the goals most cost-effectively.
When Is Energy Design Needed?
New Construction
Energy Design finds the most cost-effective energy concept for the location, use and budget, while the envelope and building systems can still be chosen freely. That way you build the right configuration from the start.
Retrofitting existing buildings
Energy Design shows how existing buildings can best be transformed: decarbonization, retrofit and maintenance. You see which measures are needed, when, and at what cost, and can prioritize your retrofit roadmap with confidence.
What Energy Design includes
A complete analysis of design options in the concept phase, with economic and technical analysis, heating and cooling load calculations and cost estimates.

OPTIMUSE analyzes which components and systems a building needs and calculates the investment, operating and life cycle cost. You see which design option pays off in the long term.

We look at the building as a whole: the envelope, the systems for heating, cooling and ventilation, and specific components. This makes the interdependencies between the systems visible.

For each design option we calculate energy demand, CO₂ impact and energy ratings, aligned with the relevant requirements. You see which option meets your sustainability goals.

You receive all design options clearly prepared and directly comparable: a solid basis for the investment decision, approval, reporting and design development.
Detailed energy and thermal simulation
Energy and thermal simulations analyze your building on a physical basis and show the most cost-effective design option for your goals and requirements.
Customers who use Energy Design














Frequently Asked Questions
Energy Design is a simulation-based comparison of design options for the building envelope and building systems. You use it early in the project, from pre-design to schematic design, for new buildings and existing ones. For new buildings, you find the most cost-effective configuration before decisions are fixed. For existing buildings, you optimize retrofit, decarbonization and maintenance and can plan the necessary measures early.
Yes, down to manufacturer level. You upload the technical data sheets of specific components, and we simulate the options using this real product data. This is not a generic comparison but a comparison of specific models with their actual performance data. You can then simulate these options further.
Yes. You upload the documents you have, such as 2D drawings in DWG format or PDFs. We use them to build the digital twin in advance, and the option studies run on it. The prerequisite is a model at LOD 250 or higher. With complete data you receive it within 3 business days, with PDFs only within 5 to 7 business days.
For each design option we calculate CRREM compliance according to v2.04, that is, when the asset becomes stranded under the respective concept. This gives the retrofit roadmap: which combination of measures postpones the stranding year by how much, and at what CapEx. Example IG Immobilien: 12 office buildings, retrofit sequence over 7 years, prioritized by stranding risk.
At its core, a dynamic thermal simulation, supplemented by further calculation methods. Depending on the question, we apply different standards, such as DIN standards or Austrian ÖNORM standards, to determine the appropriate method and the most robust result for each design option.
Once the digital twin is available, you receive the complete results within 7 business days, calculated for your goals and requirements.
Economic analyses in line with the standards, including life cycle cost and CO₂ emissions. For each design option we show transparently how it differs economically. Your individual requirements are included too, for example how options affect certification criteria.
Test Energy Design on Your Own Project
AI-powered. Efficient. Sustainable. We'll show you how to transform the future of your buildings.